top of page

TINT METER - ENFORCER II

SKU TM ENFORCER II

TM ENFORCER II

Laser Tech UK are the sole approved UK distributor for the Laser Labs, Inc Enforcer II tint meter.

Quantity

PRODUCT INFO

The Enforcer II is small, light, durable and works on side windows.  It features auto calibration, neoprene foam to help block stray light as well as cleaning debris from the window and Laser Labs, Inc proven accuracy.

Laser Labs, Inc tint meters use a light at 550nm to measure total light transmittance.  The optical detector has a photopic response that closely matches that of the human eye

The measurement reads out a value between 0% (opaque material such as cardboard) and 100% (pure air).  The Enforcer II is accurate to within plus or minus 2% and is not affected by humidity or stray light.  They are reliable from -18 to 38 C, day or night.

The Enforcer II tint meter is designed and assembled in the USA and comes with two NIST traceable reference samples.  The lighter sample is high transmittance (65% to 89%), and the darker is low transmittance (20% to 35%).

Laser Tech UK can also supply British Standards Institute (BSI UK) certified reference samples.  (Please enquire for further information).

The Enforcer II runs on a CR2032 3V coin cell batteries (included) which is good for 5000 uses and have a ten years’ shelf like.  Replacement batteries can be purchased at your local hardware, convenience or online store and are easily changeable.

OVERVIEW

Tint meters measure the amount of visible light transmitted through glass, VLT.  The measurement range goes from 100%, which is just air, to 0% which is totally black.

The Enforcer II is a small, lightweight (60g) very useful tint meter.  It can measure tint levels on any vehicle side window at any time of day or night. 

Tint Meter Maintenance
The Tint Meter does not require any user maintenance other than an occasional battery change.  Lithium button cells powering the Tint Meters have a 10 year shelf life.  The Enforcer II only uses power when on a window and will power down if left on the window for a few minutes.

SPECIFICATION

Wavelength

550 nanometers

Bandwith

120 nanometers

Accuracy

+/- 2%

Repeatabilty

1%

Measurement range

0% to 100%

Temperature range

-18 to 38C (0º to 100ºF)

Sample thickness

0.0mm to 6.35mm

Sample size

25 x 75 mm minimum

Testing time

4 seconds

Effect of stray light

Not affected

Lamp life

10 years

Power source

1 lithium CR2032, 3V battery (included)

Weight

60g

Dimensions

95 x 45 x 30mm

+44 (0)1926 298686

B2 Harris Road, Warwick, UK, CV34 5JU

© 2025 by Laser Tech UK 

Comp Reg   : 

VAT Reg No : 

​WEEE Reg   :

12203874

 GB335651207

 WEE/MM9218AA

bottom of page